Electric Tankless MODEL CFLWD-54-KW

  • No ramp up time as the first drop of water from the unit is at temperature

  • Minimal working parts provides a long mean time to failure

  • Low watt density elements increase the product’s life and reliability

  • Low watt density elements lasted a minimum of ten times as long in a destructive test as the standard high watt density product used in ours and others general purpose products.

  • Air relief system and unique water flow make this unit more reliable than other tankless units

  • Individually fused elements

  • Six individual circuits in this unit keep the customer from being out of service if one circuit fails

  • The optional flow switch for $200 assures water flow thru the unit before the unit will heat thus providing extra protection against supply shut offs

  • An optional electronic temperature control at $300 allows user to adjust the system temperature in recirculating systems

  • Optional operating lights at a cost of $150 show which elements are on at any time.

  • Produces 184K BTUs per hour

  • All common three phase voltages available

  • Fixed output temperatures with numerous selections available

  • Stainless steel heat exchangers

  • ¾ or 1” In/Out piping and valves included

  • Certified to CSA STD E60335-2-35

  • Conforms to UL 499

  • Flows 30 GPM+ thru optional 1” fittings

  • Heats 5 gallons per minute or 300 gallons per hour by 74 degrees Fahrenheit

  • Heats 25 gallons per minute or 1500 gallons per hour by 15 degrees Fahrenheit
Click on smaller images to see a different view.
Mouse over larger pic for expanded view


Suggested Retail Price $5,740

Contractors or Distributors

Click here to request a Quote for the CFLWD-54-KW
 
 

Used in food processing, restaurants, multiple sink applications, sanitization, safety showers, eye wash stations and showers.

You can view customer application drawings on our applications pages for all our units(see menu)
and see specific applications for this unit below.

IndustryApplication
Food Cookie Company Application
Government Rehab
Healthcare Dialysis Dept
Housing Hotel #2
Restaurant Large Application 1
Restaurant Large Application 2
     
Phase of Electricity Required   Three
Individually Fused elements Yes
Phase Voltages n/a means not available
Full Load Amp Draw at 575 N/A
Full Load Amp Draw at 480   65
Full Load Amp Draw at 240 81
Full Load Amp Draw at 208   150
Y or Delta Configuration for 480 Volt Units   Delta
In/Out Pipe Size   3/4 or 1"
Heat Exchanger Material   316 SS
Enclosure Size W x H x D   24.75 x 30 x 9
Area Needed To Install and Repair   46 x 53 x 40
Enclosure Size Including Fittings   33.25 x 42 x 9
Enclosure Rating   Nema 3 - Nema 4 Available
Mounted at Customer Site Via Brackets at top and bottom of box
Efficiency Rating 98.90%
Operating Pressure Range 0-150 PSI
BTU Output Per Hour 184,248
Temperature Output Maximum 200
Output Temperature Adjustable 90,110,125,145,155,185,200
Output Temperature Settings Available No, With the optional ETC you can adjust thetemperature in recirculation systems
Temperature Output Minimum 90
Freeze Protection Optional
Number of Over Temp Protections Two
Minimum Flow To Engage 2.0
Maximum Flow in G.P.M. at 60 PSI 32
Shipping Weight 150 Lbs.
Shipping Box Size Skid Only
Warranty 2 years electrical parts
5 years on heat exchanger

NEMA 4 Enclosures to allow outside installation
Mixing Valves to allow two temperature outputs from the same unit
Temperature Controls
Switches
Pumps for recirculating systems

Tankless, Inc. 2060 Whitfield Park Ave., Sarasota, FL 34243 Phone: 1-800-TANKLESS 1-800-826-5537
Home | About | Contact Us | Residential Heaters | Commercial Heaters | Pool And Spa Heaters | Radiant Heaters | FAQ'S
Privacy Policy | Links

 

 

tankless hot water and solar heaters

Copyright © 2017 Tankless Inc. All Rights Reserved.