Electric Tankless MODEL CELWD-72-KW
  • The low watt density elements used in this model last ten times as long in destructive tests with air. Because they are much larger and therefore run cooler they are also less susceptible to hot spot creation on the sheathing.

  • Special air relief system affords increased reliability

  • Dynamic load balancing insures even element wear to improve longevity

  • Electronic controls with minimal working parts

  • Standard NEMA 3 enclosure provided with NEMA 4 available

  • Output temperature adjustable in one degree increments from 60 to 185 F

  • LED shows output temperature setting and flashes actual temperature if the
    customer is asking for more heat than is available

  • 316 Stainless steel heat exchangers

  • Individually fused elements

  • 3/4 " in/out stainless pipe and valves included

  • Flows 30 GPM

  • Certified to CSA STD E60335-2-35

  • Conforms to UL 499

  • Heats 5.4 gallons per minute or 328 gallons per hour by 60 degrees Fahrenheit

  • Accurate to +/- 1 degree F

  • Three standard over temperature protections

  • Our most popular size unit

  • 245 K BTUs per hour
Click on smaller images to see a different view.
Mouse over larger pic for expanded view


Suggested Retail Price $7,065

Contractors or Distributors

Click here to request a Quote for the CELWD-72-KW
 

Used in food processing, restaurants, multiple sink applications, sanitization, safety showers, eye wash stations and showers.

You can view customer application drawings on our applications pages for all our units(see menu)
and see specific applications for this unit below.

Industry Description
Automotive Showers/Sinks
Automotive Showers
Health clubs Small application
Healthcare Dialysis #3
Food Vegetable processing 1
Food Brewery
Miscellaneous Safety Shower #2
Healthcare Dialysis 1
Healthcare Dialysis 2
Healthcare Safety Shower
Misc. Safety Shower 2
   
     
Phase of Electricity Required   Three
Individually Fused elements Yes
Phase Voltages n/a means not available
Full Load Amp Draw at 575 72
Full Load Amp Draw at 480   86
Full Load Amp Draw at 240 172
Full Load Amp Draw at 208   200
Y or Delta Configuration for 480 Volt Units   Delta
In/Out Pipe Size   3/4 or 1"
Heat Exchanger Material   316 SS
Enclosure Size W x H x D   24.75 x 32 x 8
Area Needed To Install and Repair   48 x 56 x 40
Enclosure Size Including Fittings   31.5 x 44 x 8
Enclosure Rating   Nema 3 - Nema 4 Available
Mounted at Customer Site Via Brackets at top and bottom of box
Efficiency Rating 98.90%
Operating Pressure Range 0-150 PSI
BTU Output Per Hour 245,664
Temperature Output Maximum 185
Output Temperature Adjustable Yes- 1 Degree Increments
Output Temperature Settings Available 60-185 F
Temperature Output Minimum 60
Freeze Protection Yes (Standard)
Number of Over Temp Protections Three
Minimum Flow To Engage 2.0
Maximum Flow in G.P.M. at 60 PSI 32
Shipping Weight 150 Lbs.
Shipping Box Size Skid Only
Warranty 2 years electrical parts
5 years on heat exchanger

NEMA 4 Enclosures to allow outside installation
Mixing Valves to allow two temperature outputs from the same unit
Temperature Controls
Switches
Pumps for recirculating systems

Tankless, Inc. 2060 Whitfield Park Ave., Sarasota, FL 34243 Phone: 1-800-TANKLESS 1-800-826-5537
Home | About | Contact Us | Residential Heaters | Commercial Heaters | Pool And Spa Heaters | Radiant Heaters | FAQ'S
Privacy Policy | Links

 

 

tankless hot water and solar heaters

Copyright © 2017 Tankless Inc. All Rights Reserved.